Integrated validation starts with a measurable product requirement.

Consider the retention force of a press-fit assembly. The design team defines how to measure it and what counts as a pass. Process engineers identify the pressing conditions that consistently meet the requirement. Equipment engineers verify that the machine can reproduce those conditions. At the final review, the teams bring all three sets of evidence together for the same physical samples to decide whether pilot production can begin.

How a design change reaches the test bench

Suppose a designer changes the tolerance on a mating part. Updating the 3D model of the station is straightforward. The harder question is whether the existing fixture, press recipe and previous retention-force tests still support the revised design. In this architecture, OpenUSD brings the workpiece, fixture, machine and sensors together in a versioned station scene. Engineering records link requirements to experiments and approvals. Product configuration, operation ID and test case connect the scene to those records.

SystemWhat it managesWhat the next team receives
CAD, PLM and specialist engineering analysis (CAE)Controlled drawings, materials, tolerances, design configurations and analysis results for specified conditionsAn approved design baseline and hypotheses that still need testing
Omniverse and OpenUSDReferences to workpiece, fixture and machine assets in a composed station scene, with collision geometry, joints and sensors configured for the intended useA reproducible scene configuration and results from pose and motion checks
Process testing and machine controlTest conditions, recipes, measured press curves, controller programs and I/O timingA process window with a defined range of applicability and recorded machine sequences that engineers can replay
Test bench and quality systemDimensions, performance, batch, deviations and retest results linked to individual samplesA release decision for a specific product and equipment configuration

Omniverse provides libraries and tools for building simulation applications. Teams can use Isaac Sim, which is built on Omniverse libraries, for robotics and sensor tasks. For material deformation or contact stress, engineers select a specialist solver validated for the question at hand. Each scene object should carry its source-system ID and revision so a reviewer can trace a fixture to its drawing or a motion test to the scene configuration used for that run. NVIDIA Omniverse · NVIDIA Isaac Sim

Four handoffs at one press-fit station

Product design | Define how to measure retention force

Design and quality engineers agree on the load direction, clamping method, test speed and acceptance range for the retention-force test. They use tolerance stack-up analysis, specialist analysis and sample comparisons to check whether mating dimensions and material properties explain the observed performance. If samples with the same measured dimensions still show substantial variation in retention force, material and surface condition become factors for further testing.

The design team hands over the drawing revision, critical-to-quality characteristic (CTQ), datums, tolerances, measurement method and supporting sample results. After CAD conversion to USD, the team checks units, coordinates, assembly hierarchy and key dimensions at the mating surfaces. Process engineers can then identify the operation that establishes the characteristic. The controlled drawing remains the authority for the tolerance and the configurations to which it applies.

Process development | Establish a defensible press-fit window

Process engineers select candidate factors such as mating dimensions, incoming material lot, insertion depth and press speed. They use design of experiments (DOE) to test combinations. For each sample, they retain the machine settings, measured force–displacement curve and final retention force. If identical settings produce different results across lots, the team examines how lot and process parameters interact before deciding whether to use lot-specific recipes or narrow the window.

Process and quality engineers confirm the window at its center and boundaries using representative incoming parts, then approve its scope. Equipment engineers receive the allowable range, measurement location, sampling requirements and response to an out-of-range result. If the acceptance criterion uses final displacement, the teams must specify whether it refers to press-axis travel or actual workpiece displacement relative to the datum. Fixture deflection can make those readings differ enough to change the verdict.

Equipment validation | Run the same test cases on the virtual and physical stations

Use the OpenUSD scene to check loading clearance, travel and interference. Select SimReady checks for the intended task. Clearance checks require accurate geometry and coordinates. Motion and contact tests also require joint definitions, collision shapes and relevant physical properties calibrated against measurements. For robotic loading and unloading, Isaac Sim can help assess reachability and sensor fields of view.

Controls engineers map states such as clamp confirmed, press enabled, end position reached and clamp released to an I/O table that records signal direction, units and timestamps. They verify the controller interface, scan cycle and simulation time step before choosing software-in-the-loop or hardware-in-the-loop testing. For a normal cycle, a missing part, a position timeout and a reset, they record both expected and observed timing. After installation, the team uses the actual fixture and representative parts to recheck positioning repeatability, press curves and cycle time. Site personnel verify safety functions under the applicable acceptance procedure.

Integrated validation | Match predictions, machine behavior and product performance sample by sample

Before testing, the quality lead freezes the revisions of the product, material, fixture, recipe, controller program, scene and measurement method. The team agrees on sample coverage and acceptance thresholds. It runs the same nominal, boundary and fault cases on the virtual and physical stations. Each physical sample ID links incoming dimensions, the press curve, alarms, final retention force and test-bench records. The corresponding operating condition and test-case ID link those observations to the simulation run.

Validation questionEvidence to compareDecision
Can the model support this decision?Predicted and measured pose, displacement or timing under the same conditionsRestrict the model’s use if the deviation exceeds the agreed limit
Can the equipment execute the process consistently?Actual press curves, repeatability, cycle time and fault response across parts and fixturesReturn to equipment or controls engineering if the machine cannot stay within the window
Do parts made within the window meet the product requirement?Measured parameters and final retention force for each sample, including failures at the boundariesInvestigate false accepts and lot differences, then review the process window or design margin
Under what conditions can pilot production proceed?Test coverage, residual risks, traceable samples and sign-off by accountable ownersSpecify the product revision, eligible lots, pilot scope and stop criteria

Consider a sample for which press-axis travel is within limits but final retention force is too low. First check the test bench against a reference sample. Then compare axis travel with actual insertion depth. If the discrepancy clusters around one fixture, isolate the affected samples and inspect that fixture. If it appears across fixtures and follows a material lot, process and design engineers take up the investigation. After correction, rerun the affected cases and keep both sets of results.

Application and limits

Start the pilot with one CTQ, one operation and one station. Verify measurement repeatability first. Design, process, equipment and quality engineers then agree on sample size, allowable error and the maximum number or rate of false accepts. At review, examine at least three results: the difference between prediction and measurement for each critical quantity, the number of samples classified as acceptable that failed physical testing, and the proportion of samples traceable to their design and equipment revisions.

The press-fit example illustrates the proposed method. Reachability, interference and sequence timing each require their own model and acceptance criteria. Predicting retention force also requires evidence on material behavior and contact conditions, supported by physical tests. The first pilot should produce a release decision tied to specific revisions, sample evidence and operating limits. When the material, fixture or controller program changes, the team can identify which tests to rerun.

Sources